Model 4110

SPECIFICATION

Input Voltage
24 VDC, 2.2 W Max.
Ion Emission
High Frequency AC (70 kHz)
Balance
Average ≤±10 V, Max ≤±30 V
Discharge Time
±1000 V to ±100 V less than 1 sec (15cm)

Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures
Monitoring
FMS monitoring interface
Air Pressure
0.1 – 0.5 Mpa
Air Inlet
6mm Inlet
Material
Enclosure: ABS Plastic
Nozzle: Teflon
Bracket: SUS
Dimensions (mm)
134W x 56H x 25D (without bracket)
134W x 62H x 25D (with bracket)
Weight
90g (with bracket)
Warranty
1 year limited warranty

Related Products

Model 4120

SPECIFICATION

Input Voltage
24 VDC, 4.1 W Max.
Ion Emission
High Frequency AC (70 kHz)
Balance
Average ≤±10 V, Max ≤±30 V
Discharge Time
±1000 V to ±100 V less than 1 sec (15cm)

Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures
Monitoring
FMS monitoring interface
Air Pressure
0.1 – 0.5 Mpa
Air Inlet
6mm Inlet
Detection Method
Diffuse reflection
Detection Distance
≤ 1m
Response Time
≤ 1ms
Initial activation time is less than 500ms, Normal operation time is less than 1ms for recovery.
IR Sensor
Light On / Dark On (2 step operation)
Ambient Illumination
Sunlight : ≤ 11,000 Lux,
Incandescent Lamp : ≤ 3,000 Lux (Receiving surface illumination)
Material
Enclosure: ABS Plastic
Nozzle: Teflon
Bracket: SUS
Dimensions (mm)
134W x 62H x 40D (with bracket)
Weight
170g (with bracket)
Warranty
1 year limited warranty

Related Products

Model 470

SPECIFICATION

Input Voltage
24 VDC, 2 W Max.
Ion Emission
Steady-state DC Technology
Balance
Less than ±15 V peak
Discharge Time
±1000 V to ±100 V less than 1 sec (15cm)

Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures
Air Pressure
0.1 – 0.5 Mpa
Air Inlet
6mm Inlet
Material
Enclosure: ABS plastic
Nozzle: Teflon
Dimensions (mm)
154W x 162H x 30D
Weight
215g
Warranty
1 year limited warranty

Related Products

Selection

Model 472A

SPECIFICATION

Input Voltage
24 VDC, 2 W Max.
Ion Emission
Steady-state DC Technology
Balance
Less than ±15 V peak
Discharge Time
Less than 2 sec with Single Crystal Silicon (0.3 Mpa / 15cm)
Less than 1 sec with Tungsten Emitter (0.3 Mpa / 15cm)

Emitter Points
Single Crystal Silicon or Tungsten emitter
Alarm
Visual & Audio alarm operate for power failures
Air Pressure
0.1 – 0.5 Mpa
Filter Efficiency
99.99% at 0.1μm
Air Inlet
6mm Inlet
Material
Enclosure: ABS plastic
Nozzle: Teflon
Dimensions (mm)
Model 472: 154W x 162H x 30D
Model 472C: 420W x 125H x 80D
Weight
Model 472: 210g
Model 472C: 1.5kg
Warranty
1 year limited warranty

Related Products

Selection

Model 3900

SPECIFICATION

Model 3940 기준
Input Voltage
100 – 240 VAC, 1A Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±20 V
Discharge Time
Less than 5 sec at 1200 mm (high fan speed)
Air Flow
100 ~ 150 CFM, 3 step fan speed adjustment
Alarm
A visual and audio alarm is activated when high voltage power unit failures.
Monitoring
FMS 8 channel terminal
Operating Environment
Temperature : 15 – 35°C
Humidity : 35 – 75 % RH
Material
Enclosure & Filter: ABS plastic
Emitter Points: Tungsten (replaceable)
Bracket: ABS plastic
Dimensions (mm)
1200W x 118H x 180D
Warranty
2 year limited warranty

Selection

Model 3800

SPECIFICATION

Model 3820 기준
Input Voltage
100 – 240 VAC, 1A Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±10 V
Discharge Time
Less than 1 sec at 450 mm (high fan speed)
Air Flow
100 ~ 150 CFM, 3 step fan speed adjustment
Alarm
A visual and audio alarm is activated when high voltage power unit failures.
Monitoring
FMS 8 channel terminal
Operating Environment
Temperature : 15 – 35°C
Humidity : 35 – 75 % RH
Material
Enclosure & Filter: ABS plastic
Emitter Points: Tungsten (replaceable)
Bracket: ABS plastic
Dimensions (mm)
680W x 118H x 180D
Warranty
2 year limited warranty

Selection

Model 3700

SPECIFICATION

Model 3730 기준
Input Voltage
100 – 240 VAC, 1A Max.
Ion Emission
Steady-state DC Technology
Ion Balance
<±5 V
Discharge Time
Less than 1 sec at 30 cm (high fan speed)
Air Flow
165 CFM
Alarm
A visual and audio alarm is activated when high voltage power unit failures.
Monitoring
RJ-45 terminal
Operating Environment
Temperature : 15 – 35°C
Humidity : 35 – 75 % RH
Material
Enclosure & Filter : ABS plastic
Emitter Points : Tungsten (replaceable)
Bracket : Aluminum
Dimensions
1000W x 70H x 180D (without bracket)
1000W x 120H x 180D (with bracket)
Warranty
2 year limited warranty

Selection

Model 3890

SPECIFICATION

Input Voltage
100 – 240 VAC, 1A Max.
Ion Emission
Steady-state DC Technology
Balance
<±10 V
Discharge Time
±1000 V to ±100 V less than 1 sec (30cm, high fan speed)

Air Flow
165 CFM
Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures and out of balance
Monitoring
RJ-45 Terminal interface
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
422W x 190H x 107D (without bracket)
422W x 225H x 115D (with bracket)
Weight
2.6 kg
Warranty
2 year limited warranty

Model 3890E

SPECIFICATION

Input Voltage
100 – 240 VAC, 1A Max.
Ion Emission
Steady-state DC Technology
Balance
<±10 V
Discharge Time
±1000 V to ±100 V less than 1 sec (30cm, high fan speed)

Air Flow
165 CFM
Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures and out of balance
Monitoring
RJ-45 Terminal interface
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
422W x 190H x 107D (without bracket)
422W x 225H x 115D (with bracket)
Weight
2.6 kg
Warranty
2 year limited warranty

Model 3810

SPECIFICATION

Input Voltage
24 VDC, 10.6 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±5 V
Discharge Time
±1000 V to ±100 V less than 1 sec (30 cm)
Air Flow
138 CFM
Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures and out of balance
Monitoring
FMS monitoring interface
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
148W x 185H x 77D (without bracket)
188W x 205H x 77D (with bracket)
Weight
1kg (with bracket)
Warranty
2 year limited warranty

Model 3810F

SPECIFICATION

Input Voltage
24 VDC, 10.6 W Max.
Ion Emission
Steady-state DC Technology
Balance
<±5 V
Discharge Time
±1000 V to ±100 V less than 1 sec (30 cm)
Air Flow
150 CFM
Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures and out of balance
Monitoring
FMS monitoring interface
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
148W x 185H x 77D (without bracket)
188W x 205H x 77D (with bracket)
Weight
1kg (with bracket)
Warranty
2 year limited warranty

Model 310SE

SPECIFICATION

Input Voltage
24 VDC, 9.3 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±20 V
Discharge Time
±1000 V to ±100 V less than 2 sec (30cm)
±1000 V to ±100 V less than 5 sec (60cm)
Air Flow
100 CFM
Alarm
Visual & Audio alarm operates when ionizer can not maintain balance limit and power failures.
Monitoring
RJ-45 terminal Interface
Operating Environment
Temperature: 15 – 35°C
Humidity: 35 – 75 % RH
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
125W x 135H x 70D (without bracket)
152W x 155H x 70D (with bracket)
Weight
580g (with bracket)
Warranty
2 year limited warranty

Model 310S

SPECIFICATION

Input Voltage
24 VDC, 7.2 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±20 V
Discharge Time
±1000 V to ±100 V less than 2 sec (30cm)
±1000 V to ±100 V less than 5 sec (60cm)
Air Flow
100 CFM
Alarm
Visual & Audio alarm operates when ionizer can not maintain balance limit and power failures.
Monitoring
RJ-45 terminal Interface
Operating Environment
Temperature: 15 – 35°C
Humidity: 35 – 75 % RH
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
125W x 135H x 70D (without bracket)
152W x 155H x 70D (with bracket)
Weight
580g (with bracket)
Warranty
2 year limited warranty

Model 310E

SPECIFICATION

Input Voltage
24 VDC, 6.9 W Max
Ion Balance
<±10 V
Ion Emission
Steady-state DC Technology
Discharge Time
±1000 V to ±100 V less than 3 sec (30 cm)

Air Flow
60 CFM
Emitter Points
Tungsten 99.99%
Alarm
Visual & Audio alarm operate for power failures and out of balance
Monitoring
RJ-45 Terminal interface
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
125W x 135H x 70D (without bracket)
152W x 155H x 70D (with bracket)
Weight
580g (with bracket)
Warranty
2 year limited warranty

Model 360S

SPECIFICATION

Input Voltage
24 VDC, 4.8 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±10 V
Discharge Time
±1000 V to ±100 V less than 5 sec (30cm)
±1000 V to ±100 V less than 10 sec (60cm)
Air Flow
34 CFM
Alarm
Visual & Audio alarm operates when ionizer can not maintain balance limit and power failures.
Monitoring
FMS Interface
Operating Environment
Temperature: 15 – 35°C
Humidity: 35 – 75 % RH
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
80W x 110H x 64D (without bracket)
105W x 120H x 64D (with bracket)
Weight
340g (with bracket)
Warranty
2 year limited warranty

Model 360A

SPECIFICATION

Input Voltage
24 VDC, 4.8 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
<±10 V
Discharge Time
±1000 V to ±100 V less than 5 sec (30cm)
±1000 V to ±100 V less than 10 sec (60cm)
Air Flow
27 CFM
Alarm
Visual & Audio alarm operates when ionizer can not maintain balance limit and power failures.
Monitoring
FMS Interface
Operating Environment
Temperature: 15 – 35°C
Humidity: 35 – 75 % RH
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
80W x 110H x 64D (without bracket)
105W x 120H x 64D (with bracket)
Weight
340g (with bracket)
Warranty
2 year limited warranty

Model 360E

SPECIFICATION

Input Voltage
24 VDC, 4.8 W Max
Ion Emission
Steady-state DC Technology
Ion Balance
Less than ±5V
Discharge Time
±1000 V to ±100 V less than 5 sec (30cm)
±1000 V to ±100 V less than 10 sec (60cm)
Air Flow
27 CFM
Alarm
Visual & Audio alarm operates when ionizer can not maintain balance limit and power failures.
Monitoring
FMS Interface
Operating Environment
Temperature: 15 – 35°C
Humidity: 35 – 75 % RH
Material
Enclosure & Filter Cover: ABS plastic
Bracket: Aluminum
Dimensions (mm)
80W x 110H x 64D (without bracket)
105W x 120H x 64D (with bracket)
Weight
340g (with bracket)
Warranty
2 year limited warranty

Model 6200

SPECIFICATION

Housing
Aluminum Anodizing
Inner
Teflon and ABS
Emitters
SUS 304 Stainless Steel
Effective Length
80mm – 2980mm
Overall Length
100mm – 3000mm
Mounting Distance
20mm – 300mm from target surface
Warranty
1 year limited warranty

Related Products

Part Numbers

Model 6100

SPECIFICATION

Housing
Aluminum Anodizing
Inner
Teflon and ABS
Emitters
SUS 304 Stainless Steel
Effective Length
80mm – 2980mm
Overall Length
100mm – 3000mm
Mounting Distance
20mm – 300mm from target surface
Warranty
1 year limited warranty

Related Products

Part Numbers

Model 7110

SPECIFICATION

Input Voltage
24 VDC, 10.1 W Max. (at 7 kV Output)
Output Voltage
±7 k VDC, 100V Adjustment
Ion Emission
Pulsed AC Technology
Balance
Avg. <±30 V
Discharge Time
±1000 V to ±100 V less than 1 sec (30cm)
Timing / Frequency
1 ~ 50 Hz Frequency
Display
3 digit FND display
Control
Short/Long distance factory set, user define mode
Emitter Points
Tungsten 99.99%
Alarm
Visual (LED) & Audio (Buzzer): Normal (Green), Cleaning (Yellow), Power (Red)
Monitoring
RJ-45 monitoring interface
Air Pressure
0.1~0.3 MPa
Air Inlet
8mm Inlet
Material
Enclosure & Bracket: ABS plastic
Nozzle: Polycarbonate
Dimensions (mm)
124H x 50D x L (300, 400, 500, 600, 800, 1000, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000)
Weight
1.2kg (1000mm length)
Warranty
1 year limited warranty

Related Products

Part Numbers

Model 2100

SPECIFICATION

Input Voltage
24 VDC, 3 W Max.
Output Voltage
±7 k VDC, 100V Adjustment
Ion Emission
Pulsed DC Technology
Balance
Adjustable for each applications
Timing/Frequency
0.1-99.9 sec for each polarity
0.1 sec resolution adjustment
Display
3 digit FND display
Control
High voltage output and timing adjustment for each polarity
Emitter Points
Silicon Emitter compatible to ISO 14644-1 Class 1
Titanium Emitter compatible to ISO 14644-1 Class 3
Alarm
Visual (LED): clean, HVP fail alarm
Audio (Buzzer): HVP fail, cleaning
Monitoring
RJ-45 monitoring interface
Material
Enclosure & Bracket: ABS plastic
Nozzle: Polycarbonate
Dimensions (mm)
124H x 50D x L (600, 700, 900, 1200, 1600, 2000)
Weight
1.2kg (1000mm length)
Warranty
1 year limited warranty

Related Products

Part Numbers

Model 7300

SPECIFICATION

Input Voltage
24 VDC
Output Voltage
±5 k VAC
Ion Emission
Steady-state DC Technology
Balance
< ±50 V
Discharge Time
±1000 V to ±100 V less than 2 sec (30cm)
Emitter Points
Tungsten 99.99%
Alarms
Visual & Audio alarm operate for power failure
Monitoring
RJ-45 monitoring interface
Air Pressure
0.1-0.3 MPa
Air Inlet
8mm Inlet
Material
Enclosure & Bracket: ABS
plastic Nozzle: Polycarbonate
Dimensions (mm)
124H x 50D x L (300, 400, 500, 600, 1200)
Weight
600g (300mm length)
Warranty
2 year limited warranty

Related Products

Part Numbers

Model 7380d

SPECIFICATION

Input Voltage
24 VDC, 300 Watt Max.
Output Voltage
±4kV DC, 10V Resolution Adjustment
Ion Emission
Steady-State DC Technology
Balance
Less than ±5V
Discharge Time
Less than 2.0 seconds at 300mm
Display
4 digit LED display
Output Control
High voltage output and timing adjustment for each polarity
Emitter Points
Silicon Emitter compatible to ISO 14644-1 Class 1
Alarms
Visual & Audio alarm operates for ion balance HV power failures
Monitoring
RJ-45 monitoring interface
Material
Enclosure & Bracket: ABS plastic
Nozzle: Polycarbonate
Dimensions (mm)
62.5H x 30D x 350L mm
Warranty
1 year limited warranty

Related Products

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Model 2200

SPECIFICATION

Input Voltage
24 VDC, 5.7 W Max.
Output Voltage
14 kV DC, 100 V resolution adjustment
Ion Emission
Pulsed DC Technology
Display
3 digit LED display
Control
Voltage, On time and Off time are adjusted by Model 5711R
Timing
ON Time: 0.1 – 99.9 sec / 0.1 sec resolution adjustment for each polarity
Connectors
RJ-45 modular terminal
Emitter Points
Single Crystal Silicon Emitter Point Tungsten 99.99%, All emitter points are replaceable
Alarm
Visual & Audio alarm operates voltage feedback monitoring, power, and sync failures
Monitoring
Relay Output
Operation Modes
Pulsed DC and individual ON/OFF control
Operating Environment
Temperature: 15 – 35°C, nominal
Humidity: 20 – 60% RH, non-condensing
Material
ABS plastic, Polycarbonate
Dimensions (mm)
124H x 50D x 800, 1000, 1200, 1400, 1600, 1800 and 2000L
Warranty
1 year limited warranty

Related Products

Part Numbers

Model 2300

SPECIFICATION

Input Voltage
24 VAC, 1.2 W Max
Output Voltage
±10 kV DC, 100 V resolution adjustment
Ion Emission
Pulsed DC Technology
Balance
Adjustable for each applications
Display
3 digit LED display
Control
Voltage, On time and Off time are adjusted by Model 5711R or Model 6300 series controller
Timing
ON Time: 0.1 – 15.0 sec / 0.1 sec resolution adjustment
OFF Time: 0.1 -10.0 sec / 0.1 sec resolution adjustment
Connectors
RJ-45 Ethernet Type
Emitter Points
Single Crystal Silicon or Titanium. All emitter points are replaceable
Cleanliness
Silicon Emitter compatible to ISO 14644-1 Class 1
Titanium Emitter compatible to ISO 14644-1 Class 3
Emitter Rods
150, 300, 450, 600, 750 and 900 mm. Custom length is available
Alarm
Visual & Audio alarm operate voltage feedback monitoring, cleaning cycle, sync and polling failures
Monitoring
RS-485 terminal on Model 6300 series controller
Operation Mode
Pulsed DC, stand-by and individual ON/OFF control
Operation Environment
Temperature: 15-35 °C, nominal
Humidity: 20 -60% RH, non-condensing
Material
ABS plastic, Polycarbonate
Dimensions (mm)
500W x 46H x 42D
Weight
410g (without rods)
Warranty
2 year limited warranty

Related Products

Model 6300 Controller

Part Numbers

Model 2400

SPECIFICATION

Input Voltage
24 VAC, 1.4 W Max.
Output Voltage
±12 kV DC, 100 V resolution adjustment
Ion Emission
Pulsed DC Technology
Balance
Adjustable for each applications
Display
4 digit LED display
Control
Voltage, On time and Off time are adjusted by Model 5711R or Model 6300 series controller
Timing
ON Time: 0.1 – 15.0 sec / 0.1 sec resolution adjustment
OFF Time: 0.1 -10.0 sec / 0.1 sec resolution adjustment
Connectors
RJ-11 modular terminal
Emitter Points
Single Crystal Silicon or Titanium. All emitter points are replaceable
Cleanliness
Silicon Emitter compatible to ISO 14644-1 Class 1
Titanium Emitter compatible to ISO 14644-1 Class 3
Emitter Rods
150, 300, 450, 600, 750 and 900 mm. Custom length is available
Alarm
Visual & Audio alarm operate voltage feedback monitoring, cleaning cycle, sync and polling failures
Monitoring
RS-485 terminal on Model 6300 series controller (Max. 120 units)
Operation Mode
Pulsed DC, stand-by and individual ON/OFF control
Operation Environment
Temperature: 15-35 °C, nominal
Humidity: 20 -60% RH, non-condensing
Material
ABS plastic, Polycarbonate
Dimensions (mm)
450W x 30H x 36D
Weight
410g (without rods)
Warranty
2 year limited warranty

Related Products

Model 6300 Controller

Part Numbers